The setup

Fix the mounting face, apply a downward force at the load point, and read the stress distribution. The peak stress concentrates at the inner corner of the bend — exactly where a sharp inside radius usually lives.

  • Peak stress at the bend corner
  • Stress drops fast away from the corner
  • Fasteners see prying loads, not just shear

The fix is a 30-cent change: increase the inside bend radius and add a small fillet. Peak stress drops roughly 40%, and the bracket stops failing in testing.